Freshly framed ADU with exposed studs and golden-hour light raking through parallel shadows on the subfloor, main house visible beyond

ADU Pre-Inspection · California

Every Stud,
Every Setback,
Before the City Arrives.

One inspector. Laser setbacks, joist hangers, Title 24 — checked before your correction notice becomes a stop-work order.

Scroll

340+ADUs inspected
97%Pass first city review
48hReport turnaround
IRC · Title 24Code authority

Finding 01

Fire Blocking & Joist Hangers

The most-cited framing violation in California ADU inspections — invisible once sheathing goes on.

Schedule My Inspection
Exposed wood framing of ADU wall showing missing fire blocking between floor and ceiling intersection, raw lumber without proper fire-stopping material
Before · Deficiency
IRC R302.11Fire blocking gap — 14-inch opening between floor and ceiling
Corrected ADU framing with fire blocking properly installed at floor-ceiling intersection, code-compliant lumber placement visible
After · Code Compliant
IRC R502.6Joist hanger installed — nail schedule confirmed
Flagged

Fire blocking absent at floor-ceiling intersection, north wall bay 3. IRC R302.11 requires horizontal blocking at max 10-ft intervals in combustible construction.

Resolved

2×6 flat blocking installed between studs at floor line. Joist hanger nail schedule verified — 10d nails at 3-in o.c. per manufacturer spec.

Finding 02

Beam Sizing & Shear Walls

Structural findings that a city inspector may approve on paper — until the PE review catches the span table error.

Schedule My Inspection
Interior ADU framing showing undersized ridge beam spanning 14 feet without adequate support, exposed rafters and structural members visible
Before · Deficiency
IRC R802.4Undersized ridge beam — 9¼ depth insufficient for 14-ft span
Corrected structural framing with properly sized LVL beam installed, engineered lumber visible with manufacturer stamps, adequate bearing points on each end
After · Code Compliant
IRC R802.4LVL 3½×11¼ confirmed — PE stamp on file
Flagged

LVL ridge beam 3½×9¼ insufficient for 14-ft clear span under 30 PSF snow load. IRC Table R802.4.1 requires minimum 3½×11¼ or PE-stamped alternative.

Resolved

Beam upsized to 3½×11¼ LVL. PE letter on file confirming span and load path. Bearing plates added at each end per structural drawings.

Finding 03

Title 24 Ventilation & Insulation

Energy code violations that sail through framing inspection — and fail final. Caught here, they cost $400. Caught at final, they cost a month.

Schedule My Inspection
ADU attic framing showing undersized eave vents with insufficient net free area, compressed insulation batts not in contact with roof sheathing
Before · Deficiency
Title 24 §150.0(o)Vent ratio 1:375 — 40% below minimum required
Corrected ADU attic with properly sized continuous soffit vents installed, insulation batts properly placed in contact with sheathing meeting Title 24 requirements
After · Code Compliant
Title 24 §150.1(c)Continuous vent strip — ratio now 1:140, compliant
Flagged

Eave vent net free area measures 1:375 ratio — 40% below Title 24 §150.0(o) requirement of 1:150. Insulation R-15 batts compressed to R-11 effective at eave.

Resolved

Continuous soffit vent strip added, achieving 1:140 ratio. Insulation baffles installed — R-15 batts now in full contact with sheathing at eave line.

Inspection Report · Sample

What you receive
within 48 hours.

PDF · Typed · Timestamped

Permit Inspection Services

Pre-Inspection Report · ADU Framing & Energy

RPT-2026-0847

February 24, 2026

Property

2847 Mesquite Canyon Dr, Riverside, CA 92503

Stage

Framing — Pre-Sheathing

Inspector

M. Callahan · CA HVI #24-0193

Findings Summary

F-01North wall, bay 3Missing fire blocking at floor-ceiling intersection per IRC R302.11
FlaggedIRC R302.11
F-02Ridge beam, center spanLVL beam undersized for 14-ft clear span — requires PE letter or upsized to 3½×11¼
FlaggedIRC R802.4
F-03South wall, window rough openingKing stud trimmer count insufficient for 4-ft opening width
FlaggedIRC R602.7
F-04Attic, eave ventsNet free area 40% below Title 24 ventilation ratio requirement
FlaggedTitle 24 §150.0(o)
F-05Bathroom, exterior wallR-15 batts compressed to R-11 effective — insulation not in contact with sheathing
AdvisoryTitle 24 §150.1(c)
F-06Subfloor, perimeterJoist hangers installed — nail schedule complete, bearing confirmed
PassIRC R502.6
F-07Foundation sillAnchor bolt spacing 6-ft on center — complies with seismic zone D
PassIRC R403.1.6
4 Flagged
1 Advisory
2 Pass

Reinspection required before sheathing

Sample report — identifying details changed · Format identical to delivered document

Book an Inspection

Schedule My
Inspection.

Available within 3–5 business days. Reports delivered within 48 hours of site visit.

Street address of the ADU project site

Select your current build phase

ADU Inspection Checklist

47-point pre-inspection guide covering framing, energy, and structural code items. Used by contractors across the Inland Empire.

Why Permit

Catches what city inspectors miss

340+ ADU inspections. 97% of clients pass their first city review after a Permit pre-inspection.

48-hour report turnaround

Typed, timestamped, code-cited PDF. Contractor-ready for your subcontractor correction list.

IRC · Title 24 · IECC authority

Every finding cites the specific section. No vague notes — exact code language your permit tech expects.

One inspector, every time

Not a franchise. One set of eyes, trained on California ADU code, who knows your project by the time framing starts.

"Got a correction notice on a Friday. Marcus was on-site Monday, report in hand Wednesday. We pulled sheathing, fixed five items, and passed city framing the following Tuesday."

Derek Santamaria

Project Manager · Inland Valley Build Co., Fontana CA