Finding 01
Fire Blocking & Joist Hangers
The most-cited framing violation in California ADU inspections — invisible once sheathing goes on.
Fire blocking absent at floor-ceiling intersection, north wall bay 3. IRC R302.11 requires horizontal blocking at max 10-ft intervals in combustible construction.
2×6 flat blocking installed between studs at floor line. Joist hanger nail schedule verified — 10d nails at 3-in o.c. per manufacturer spec.
Finding 02
Beam Sizing & Shear Walls
Structural findings that a city inspector may approve on paper — until the PE review catches the span table error.
LVL ridge beam 3½×9¼ insufficient for 14-ft clear span under 30 PSF snow load. IRC Table R802.4.1 requires minimum 3½×11¼ or PE-stamped alternative.
Beam upsized to 3½×11¼ LVL. PE letter on file confirming span and load path. Bearing plates added at each end per structural drawings.
Finding 03
Title 24 Ventilation & Insulation
Energy code violations that sail through framing inspection — and fail final. Caught here, they cost $400. Caught at final, they cost a month.


Eave vent net free area measures 1:375 ratio — 40% below Title 24 §150.0(o) requirement of 1:150. Insulation R-15 batts compressed to R-11 effective at eave.
Continuous soffit vent strip added, achieving 1:140 ratio. Insulation baffles installed — R-15 batts now in full contact with sheathing at eave line.
Inspection Report · Sample
What you receive
within 48 hours.
Permit Inspection Services
Pre-Inspection Report · ADU Framing & Energy
RPT-2026-0847
February 24, 2026
Property
2847 Mesquite Canyon Dr, Riverside, CA 92503
Stage
Framing — Pre-Sheathing
Inspector
M. Callahan · CA HVI #24-0193
Findings Summary
Reinspection required before sheathing
Sample report — identifying details changed · Format identical to delivered document
Book an Inspection
Schedule My
Inspection.
Available within 3–5 business days. Reports delivered within 48 hours of site visit.
ADU Inspection Checklist
47-point pre-inspection guide covering framing, energy, and structural code items. Used by contractors across the Inland Empire.
Why Permit
Catches what city inspectors miss
340+ ADU inspections. 97% of clients pass their first city review after a Permit pre-inspection.
48-hour report turnaround
Typed, timestamped, code-cited PDF. Contractor-ready for your subcontractor correction list.
IRC · Title 24 · IECC authority
Every finding cites the specific section. No vague notes — exact code language your permit tech expects.
One inspector, every time
Not a franchise. One set of eyes, trained on California ADU code, who knows your project by the time framing starts.
"Got a correction notice on a Friday. Marcus was on-site Monday, report in hand Wednesday. We pulled sheathing, fixed five items, and passed city framing the following Tuesday."
Derek Santamaria
Project Manager · Inland Valley Build Co., Fontana CA